NovelBeam has set up a full series of high precision photoelectric test equipment, is able to accurately test product properties such as size, angle, flatness, spectrum and luminous flux.
NovelBeam has established a professional QA inspector team which works closely with technical support engineers. NovelBeam is able to provide product inspection according to various standards including GB, ISO and the US Military Standard (MIL-STD).
Test Equipment
Spectrometer Varian, Inc., USA
|
Accurately measure the spectral transmission and reflectivity over UV-VIS-NIRWavelength Range: 175nm~3300nm Limit Resolution: 0.05nm Wavelength Accuracy: ±0.1nm Cutoff Accuracy: OD6~OD7
|
Spectrometer SHIMADZU Corporation, Japan | Scan UV-to-VIS wavelength range, precisely test the spectral transmission and reflectivityWavelength Range: 190nm~3200nm Resolution: 0.02nm Wavelength Accuracy: ±0.3nm Cutoff Accuracy: OD5 |
Laser Interferometer Zygo Corporation, USA |
Provide high-precision measurement and analysis of flat surface, spherical surface, radius, and transmission wavefront Test Beam: 4 inch (102mm) be provided by software) |
LCS LED Characterization System LabSphere Inc., USA
|
Measure and analyze Total Luminous Flux, Total Spectral Flux, Averaged Luminous Intensity, Averaged Spectral Radiant, Intensity, Dominant Wavelength, Spectral Purity, Correlated Color Temperature, Color Rendering Index (CRI), Chromaticity Coordinates (x, y, u’, v’)Sphere Size: 2 inch Sphere Interior Coating:Spectraflect Photometric Range(Illuminant A): 0.001~150lm |
Precision Goniometer Trioptics GmbH, Germany | Measure angle, pyramidal errors of prisms, hexahedrons and other polyhedral optical components Rotary Encoder Resolution: 0.36s Rotary Encoder Absolute Accuracy: 0.5s Autocollimator Resolution: 0.01s Autocollimator Absolute Accuracy: 0.1s Single Measurement Accuracy: 1.5s |
Withstanding Voltage/Leakage Current Tester | Test the Withstanding Voltage and Leakage Current of circuit board and electronic devices Testing Voltage Range: 0.5~15kV Testing Leakage Current: 0.5~200mA Measurement Accuracy: ±(5%+3 number) |
Medical Leakage Current Tester | Test the Leakage Current of medical devices under working conditionTesting Current Range: 0~10.00/20.00(AC/DC) Measurement Accuracy: ±(5%+3 number) |
Medical Rapid Steam Sterilizer | Test the tightness and service life of medical devicesChamber Volume: 24L (Φ250×520 mm) Maximum Working Pressure: 0.22Mpa Maximum Working Temperature: 134°C Adjustment of Temperature: 105°C~134°C Timer: 0~60 min Chamber Temperature Equal: ≤ ±1°C |
Universal Testing | Test the mechanical properties of metal or non-metal materials; test the impact reliability of products under shipping and working conditions Test Range: 0.04~2KN Resolution: 0.1N Measurement Accuracy: ±1% |
Coordinate Measuring Machine | Measure the physical geometrical characteristics of mechanical parts and optical componentsMeasurement Range: 500×600×400 MPE (μm): 2.2+3L/1000 MPEP (μm): 2.4 |
SM Temperature-Humidity Chambers Thermotron Industries, USA | Provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems and improve product reliability
Temperature Range: -68°C~+177°C Humidity Range: 10%~98% Temperature and Humidity Uniformity: ±0.03°C/ ±1%RH Temperature and Humidity Control Tolerance: ±0.07°C/ ±2.5%RH |
High-precision Video Measuring Machine | Measure the dimension of mechanical parts and optical componentsMeasuring Travel: 150mm~250mm Resolution: 0.001mm Measurement Accuracy: (3+L/200) μm |
NewView Optical Surface Profilers from ZYGO, USA | Provide rapid, non-contact 3D surface measurements for R&D and product department
Measurement Repeatability: 0.1nm Rq Accuracies: <0.75% Image Depths: from <1nm to 5000um Z-scan: 4.0um/s Height Resolution: 0.1nm |